Physical:
Dimensions 8 1/4¡¨ x 6 7/8¡¨ x 2 3/4¡¨ (210 x 175 x 70 mm)
Weight 3.025 (1.37 kg) pounds with battery
Operating Temperature 32F to 122F (0C to 50C)
Storage Temperature (without battery) at -22F to 158F (-30C to 70C)
Humidity Up to 95% (non-condensing)
Altitude Up to 15,000 feet (-150 to 4570 m)
Shock Mil Std 810F method 516.5, procedure 1 (40G, 6-9ms pulse, 1/2 sine each axis)
Vibration Mil Std 810F method 514.5, category 4
Enclosure protection IEC 60529 IP24
Drop Test Mil Std 810F method 516.5 procedure 4 (1 meter drop onto any edge, corner, or surface onto 2" hardwood over concrete)
Electrical Isolation: Power Unit operates on internal battery only
External Electrical Connections No external devices are attached to the unit
Risk Current Category Internally powered equipment with defibrillator-proof BF type patient applied part (as per definition of IEC 60601-1 standard)
Document Management:
Event Documentation Internal
Internal Memory Capacity 1MB: 250 4-sec ECG samples or 3000 time stamped events
Quick Report Treatment Summary, Event Log, Test Log
Communication RS-232 via Infrared (IR) port to PC or printer
Defibrillator:
Output MRL OrbitalTM Biphasic Truncated exponential
Energy Sequence (user configurable) Shock 1: 150 J, 200 J / Shock 2: 150 J, 200 J, 300 J / Shock 3: 150 J, 200 J, 300 J, 360 J
Charge Time from ¡§Shock Advised¡¨ 4 sec. to 150 J / 8 sec. to 200 J / 15 sec. to 360 J
Analysis Time 4-16 sec.
Combined Analysis and Charge Time From start of analysis to shock ready:
from power up: Less than 20 seconds to 200 J
after 6 shocks: Less than 30 seconds to 360 J
Audible Prompts 18 audible prompts
Visual Prompts 20 text screen prompts
Controls Four buttons - On/Off, Shock, and 2 software-configurable buttons
Waveform Details See AED10 Operators Manual For Details
Pediatric Energy Reducer:
Energy Attenuation Factor:
25%, at 25 Ω, 50 Ω and 75 Ω
20%, at 100 Ω and 125 Ω
15%, at 150 Ω and 175 Ω
Display:
Type Backlit Monochrome LCD
Size 2.1” x 1.42” (54 x 36 mm)
Resolution 160 x 100
Backlight LED
Battery:
Type Non-rechargeable, LiMnO2 12V, 2.6 Ah
Capacity 60 discharges at 360 Joules to reach low battery warning.* 90 discharges typical at 360 Joules to completely exhaust the battery or 125 discharges at 200 Joules or 150 discharges at 150 Joules or 5 hours ECG monitoring
*. Capacity of discharges tested per EN 60601-2-4:2003 Clause 101.4 with the AED protocol set according to EN60601-2-4:2003 Clause 102.3.2.
Shelf Life at 25°C ± 15°C
10 years (5 years storage + 5 years standby)
5 years standby (after installation)
Note Depending on environmental conditions, patterns of use, and age, the Welch Allyn AED 10 batteries will eventually begin to indicate a low battery condition. Activities such as frequently turning on the device or leaving the device idle for an extended amount of time will decrease the life of the battery and accelerate the timeframe for indicating a low battery warning.
Battery Warranty: one year from date of purchase -- battery will be free from defects in materials and workmanship.
Electromagnetic Compatibility: See AED10 Operators Manual For Details
|